@ -705,31 +705,35 @@ public class HikariConfig implements HikariConfigMBean
|
|
|
|
|
Logger logger = LoggerFactory.getLogger(getClass());
|
|
|
|
|
|
|
|
|
|
if (connectionTimeout == Integer.MAX_VALUE) {
|
|
|
|
|
logger.warn("No connection wait timeout is set, this might cause an infinite wait");
|
|
|
|
|
logger.warn("No connection wait timeout is set, this might cause an infinite wait.");
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
if (minIdle < 0 || minIdle > maxPoolSize) {
|
|
|
|
|
minIdle = maxPoolSize;
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
if (maxLifetime < 0) {
|
|
|
|
|
logger.error("maxLifetime cannot be negative.");
|
|
|
|
|
throw new IllegalArgumentException("maxLifetime cannot be negative.");
|
|
|
|
|
}
|
|
|
|
|
else if (maxLifetime > 0 && maxLifetime < TimeUnit.SECONDS.toMillis(120)) {
|
|
|
|
|
logger.warn("maxLifetime is less than 120000ms, using default {}ms.", MAX_LIFETIME);
|
|
|
|
|
maxLifetime = MAX_LIFETIME;
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
if (idleTimeout != 0 && idleTimeout < TimeUnit.SECONDS.toMillis(30)) {
|
|
|
|
|
logger.warn("idleTimeout is less than 30000ms, did you specify the wrong time unit? Using default instead");
|
|
|
|
|
logger.warn("idleTimeout is less than 30000ms, using default {}ms.", IDLE_TIMEOUT);
|
|
|
|
|
idleTimeout = IDLE_TIMEOUT;
|
|
|
|
|
}
|
|
|
|
|
else if (idleTimeout > maxLifetime && maxLifetime > 0) {
|
|
|
|
|
logger.warn("idleTimeout is greater than maxLifetime, setting to maxLifetime.");
|
|
|
|
|
idleTimeout = maxLifetime;
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
if (leakDetectionThreshold != 0 && leakDetectionThreshold < TimeUnit.SECONDS.toMillis(10) && !unitTest) {
|
|
|
|
|
logger.warn("leakDetectionThreshold is less than 10000ms, did you specify the wrong time unit? Disabling leak detection");
|
|
|
|
|
logger.warn("leakDetectionThreshold is less than 10000ms, disabling leak detection.");
|
|
|
|
|
leakDetectionThreshold = 0;
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
if (maxLifetime < 0) {
|
|
|
|
|
logger.error("maxLifetime cannot be negative.");
|
|
|
|
|
throw new IllegalArgumentException("maxLifetime cannot be negative.");
|
|
|
|
|
}
|
|
|
|
|
else if (maxLifetime != 0 && maxLifetime < TimeUnit.SECONDS.toMillis(120)) {
|
|
|
|
|
logger.warn("maxLifetime is less than 120000ms, did you specify the wrong time unit? Using default instead.");
|
|
|
|
|
maxLifetime = MAX_LIFETIME;
|
|
|
|
|
}
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
private void logConfiguration()
|
|
|
|
|